Home > Transformers >

Compact Oil Immersed Type Transformer 11 KV - 500 KVA Rational Structure

Categories Oil Immersed Transformer
Brand Name: Pearl Electric Co.,Ltd.
Model Number: PEO-S, S9~13
Certification: KEMA, CE, CCC, ISO9001
Place of Origin: China
MOQ: 1 unit
Price: USD/RMB
Payment Terms: T/T, L/C
Supply Ability: 8000 units per year
Delivery Time: 35~50days ex-work
Packaging Details: Seaworthy wooden packing
Capacity: 30kVA~10MvA or Customized
Rated H. V.: 6.6 kv or Customized
Rated L. V.: 0.4kv or Customized
Vector Group: Dyn11 or Customized
Impedence: 4%-6% or Customized
Cooling: ONAN/ONAF or Customized
  • Product Details
  • Company Profile

Compact Oil Immersed Type Transformer 11 KV - 500 KVA Rational Structure

6.6 kV Oil - Immersed Transformer, Three Phases, Two Winding, Power Distribution


Introduction


Oil-immersed type transformer features low noise, low loss, rational structure, high quality material, scientific design, strict production technology and advanced test method. The product also has the following additional advantages:


1. High mechanic strength, great anti-short circuit capability, excellent anti-lightning impulse capability and high reliability. All these performance indexes rank first in the industry in China.


2. Excellent overload capability, capable of continuously working under 110% rated load.


3. Low loss, energy-saving, economic and maintenance free.


4. Nice appearance, small size, less installation space occupation and low engineering cost.


5. Each performance index and technical specification excels that specified in China GB, international IEC and industrial standards.


6. Hermetically sealed corrugated tank structure is adopted, thus to effectively prevent air corrosion to the oil and prolong service lifetime of the transformer.

Core:


The core is manufactured with high quality cold rolled grain-oriented silicon steel of high magnetic conductivity, and 45° Mitring and steps overlapping structure is used for core production, thus to effectively reduce no-load loss and no-load current.

HV winding:


HV winding is manufactured with high quality copper conductor, adopting optimized structure to improve electric distribution. Lightning impulse wave process is carried out for calculation and analysis, thus to improve transformer's anti-lightning impulse capability.

LVwinding:


LV winding is manufactured with high quality foil conductor, so the ampere-turn balance is excellent and the transverse magnetic flux leakage is low. The anti-short circuit capability is thus greatly improved. Oil conduit is rationally designed in the windings to increase winding's heat dispersion surface, effectively reduce temperature and improve transformer's overload capability.


Insulation Structure:


The transformer adopts class-A insulation. The HV and LV windings are arranged in concentric way. Between the windings are oil-clapboard insulation structure built with paper cylinder and small oil conduit.


Tank:


The tank is jointed with high-quality steel. Rust-removing and phosphorization processes are carried out for the tank surface, then the surface is coated with FVC anti- erosion paint, thus to effectively prevent grease pollution and chemical erosion. The appearance is nice and harmonic with the environment. The whole structure is easy for installation and maintenance. It can be widely applied in outdoor environment and under harsh conditions.


Accessories:


The transformer is equipped with HV & LV bushings, oil drain valve, earthing bolt, lifting board, rating plate, pressure relief valve and other accessories. Transformers of over 800KVA power are equipped with signaling thermometer and gas relay.


Clearances in air


When assembled with connections as in service, electrical clearances in air shall be adequate to withstand the assigned impulse withstand test voltages. This shall be demonstrated by the impulse voltage routine tests specified in 5.2 Test by the Manufacturer, during the performance of which all relevant fittings shall be in position as for service conditions.


For three-winding transformers, the tertiary bushings shall have the maximum practicable spacing between phases but shall be not less than 580 mm metal-to-metal. Note the minimum requirements for tertiary bushings and bushings for transformers of 5 MVA and above in,which also requires a minimum phase-to-phase clearance of not less than 700 mm (centre to centre of the air terminals).


Specifications:
Rated H.V.:6.6 kV, ±2×2.5%
Vector GroupDyn11/Yyn0
Rated L.V.:0.4kV
Capacity:30~2500
No-load Loss:0.13~3.20kW
Load Loss0.60~21.5kW
No-load Current:0.6~2.3%
Impedance Voltage:4/4.5/5.5%
Tap-changingOn-load Tap-changing
Cooling Method:ONAN/ONAF
Reference StandardsIEC60076
Notes: The above specifications may be customized according to customer's requirement.
Features & Advantages
1. Low loss, low noise and high reliability.
2. Excellent dynamic thermal stability and high over-load capacity.
3. Simulation analysis was carried out for the core mould design, thus to greatly reduce noise level. Simulated lightning impulse wave process was carried out for HV winding mould design, thus to greatly improve product's anti-lightning impulse capability.

Quality Compact Oil Immersed Type Transformer 11 KV - 500 KVA Rational Structure for sale
Send your message to this supplier
 
From:
To: Pearl Electric Co.,Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 