240KG Compressed Refrigerated Air Dryer 380V 50HZ Capacity 18 M3 / Min

Categories Refrigerated Air Dryer
Brand Name: ZAKF
Model Number: AD-15HTF
Certification: CE, ISO9001
Place of Origin: China
MOQ: 1 set
Price: usd$200~15000/set
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 15000set/month
Delivery Time: 3~15 workdays
Packaging Details: wooden case
Product Name: 380V 50HZ Capacity 18m3/min 240KG Compress Refrigerated Air Dryer
Capacity: 18m3/min
Power: 380V/50HZ
Compressor power: 3.5/3
Fan power: 2*90 2*150
Air pipe size: DN65
Dimension: 1360*710*1210
  • Product Details
  • Company Profile

240KG Compressed Refrigerated Air Dryer 380V 50HZ Capacity 18 M3 / Min


240KG Refrigerated Compressed Air Dryer 380V 50HZ Capacity 18 M3 / Min


380V/50HZ Power dryer


Capacity 18m3/min dryer


240KG Cooling dryer


Compress Refrigerated Air Dryer


ModelAD-15HTFAD-20HTFAD-25HTFAD-30HTFAD-40HTFAD-50HTFAD-60HTF

Capacity

(Nm3/min)

18252833455565
Power380V/50HZ380V/50HZ380V/50HZ380V/50HZ380V/50HZ380V/50HZ380V/50HZ

Compressor

Power

3.5/35.0/4.06.0/4.56.5/510/7.512/7.512/7.5
Fans power

2*90

2*150

2*90

2*190

3*90

3*150

3*150

3*190

3*190

3*240

3*240

3*380

4*240

4*240

Air pipeDN65DN80DN80DN100DN100DN125DN125
Weight240280380480620780970
DimensionLength1360136016701840200023502550
Width71071075085095010501100
High1210121015751645174019201940

Noted For Use


1) Compressed air inlet temperature is too high, the ambient temperature is too high (40 ℃ or more), the use of flow over the rated amount of air handling, voltage fluctuations of more than ± 10%, poor ventilation (winter ventilation, or room temperature will rise ), Etc., the protection circuit will play a role, light off, stop running.
2) When the air pressure is higher than 0.15MPa, the normally open automatic drainage drain can be closed. When the displacement of the cold and dry machine is too small, the drain outlet is in the open state and the air is blown out.
3) poor quality of compressed air, such as mixing with dust and oil, these stolen goods will adhere to the heat exchanger to reduce its efficiency, while drainage is also easy to failure. It is desirable to set the filter at the inlet of the dryer and to confirm that the drainage is not less than once a day.
4) The dryer's vents should be cleaned once a month with a vacuum cleaner.
6) If the use of automatic drainage, should always check its drainage function is normal. Always clean the condenser dust and so on. Always check the refrigerant pressure to determine whether the refrigerant leaks and whether the capacity of the refrigerator has changed. To check whether the temperature of the condensed water is normal.


How to deal with the Leakage of Fluoride


The most intuitive performance is the refrigerant pressure gauge is zero. How to deal with the Leakage of fluoride, the first thing is to find where is leak, it need to be patient and careful with some method. First, use the visual method, open the machine board to observe the internal machine, as the refrigerant is running, there will be compressor oil mixed in, if the freon will leak out of the lubricating oil, then carefully observe the machine inside , If there is a sheet of oil with, it is likely to be a leak. And then check the machine inside the capillary brass, that is, those thin 6 mm below the brass and the process tube, there is no break phenomenon. After the above basic inspection, the place of doubt is well marked. Then you need to add a certain pressure by the inert gas to confirm the leak. Conditional circumstances best to use nitrogen to keep pressure, there is no nitrogen gaseous freon is also OK, strictly prohibited with oxygen pressure leak, it is court death.
(Low cubic meter only refrigerant low pressure table, more than 15 cubic meters of high and low pressure two refrigerant table), pressurized to 0.2Mpa (2.0kgf (2.0kgf), the pressure of the pressure of the refrigerant, ) When the temporary stop, and then carefully listen to whether the internal leakage of the machine under the sound, if there can be found where the sound leak. If not then continue to pressurize to 0.4-0 .5 Mpa. Then find a piece of sponge dipped in soapy water, just suspect the place first check, and then check the machine inside all the connecting pipe (copper nut). If there are leaks, there will be bubbles blowing out, this process requires very careful. If the above method or did not find the leak, then unfortunately, most likely the evaporator leakage. Evaporator internal leakage treatment is too much trouble. First of all must be confirmed, you can disconnect the evaporator and refrigeration system, and then separate the pressure to confirm, if the pressure alone found that pressure can be determined. There is also a relatively simple method is to open the compressed air inlet, if the refrigerant pressure gauge in a period of time after the pressure rise, it can also be sure that the cooling system and air systems connected, because their only exchange site is the evaporator. It is also possible to determine the evaporator internal leakage.
Found after the leak is the trap, according to the different points of leakage for the flare loose these leaks, just do the corresponding fastening with the wrench, if the type of copper pipe welding leak, you need to use brazing . Brazing is the refrigeration repair industry, the most commonly used one of the skills, the so-called brazing is the use of oxygen and acetylene flame to heat the low-silver electrode and the required repair welding parts, welding rod and welding parts together so that the leakage point plugging Methods. Soldering should be the first cooling system pressure spill, and then use the brazing gun to open the first acetylene, after the appropriate point by adding oxygen, and gradually adjust the ratio of oxygen and acetylene gas, the flame into a neutral flame - oxidation flame, and then heat The required welding parts and silver electrode to dissolve the two together. Specific methods require the operator to master a certain training. Once the leak has been processed, the system needs to be pressurized again to confirm that the trap was successful.
Trapping is completed, the need for vacuum pumping system, and then add the provisions of the quality of liquid Freon (the specific number of reference to the basic configuration table), plus refrigerant from the cold and dry machine dedicated to add liquid needle valve to join. For larger machines, fluoride should be added from the high-pressure charging port first, if not a one-time plus complete the prescribed dose, and so on after starting slowly from the low pressure port to the prescribed dose.

Quality 240KG Compressed Refrigerated Air Dryer 380V 50HZ Capacity 18 M3 / Min for sale
Send your message to this supplier
 
From:
To: Dongguan City Jiubei Compressor Parts Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly