Brand Name: ESTEL
Model Number: GPAD461M54-1A
Certification: ISO9001, CE, 3C, FCC, TLC
Place of Origin: Shenzhen, China (Mainland)
MOQ: 1
Price: negotiation
Payment Terms: L/C, T/T, D/A, D/P, Western Union
Supply Ability: 20,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case
Application: industrial equipment
Input Voltage: 145~300Vac
Max. Output Current: 4A
Output Voltage: +53.5Vdc, +12Vdc
Power Factor: 0.95
Output Power: 464W
Product Name: Industrial Power Supplies
  • Product Details
  • Company Profile

Commercial Power Supply , Professional Power Supply ISO9001 CE Certification


Commercial Power Supply , Professional Power Supply ISO9001 CE Certification

Quick Details:


Place of Origin: Shenzhen, China (Mainland)Input Voltage: 145~300Vac
Brand Name: ESTELOutput Voltage: +53.5Vdc, +12Vdc
Model Number: GPAD461M54-1AOutput Power: 464W
Product Name: Industrial Power SuppliesInput Frequency 47~63Hz
Certification: ISO9001, CE, ULMax. Input Current:4A
Application: industrial equipmentPower Factor: 0.95

Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C, D/A, D/P, T/T, Western Union
Supply Ability:20,000 sets per month
Delivery Time:7-10 working days
Packaging Details:carton/wooden case

1. Description


The GPAD461M54-1A custom made industrial power supplies supports wide input voltage range (145Vac ~ 300Vac), compatible with 220Vdc~380Vdc input; with two ways output: +53.5Vdc, +12Vdc. The power system includes various protection and alarm: over-voltage protection, under-voltage protection, over-current protection, short-circuit protection, over-temperature protection, input/output alarm. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.


2. Technical Parameters


Ambient conditions
ParametersMinTypicalMaxUnitNote
Operating temperature-4075°C
Storage temperature-4085°C
Relative humidity1095%non-condensing
Atmospheric Pressure70106KPanormal operation
CoolingDevice natural conduction cooling

Input
ParameterMinTypicalMaxUnitNote
AC input voltage range145220300VacThe power supplies can work normally at ambient temperature range: -40 °C~+75 °C
AC input start voltage range150220285VacThe power supplies can start normally at ambient temperature range: -40 °C~+75 °C
DC input start voltage range220380Vdc
Max input current4A145Vac input
Input surge current40A300Vac input,25°C
AC input voltage frequency range4750/6063Hz
Input power factor0.95220Vac input, rated load

Basic output characteristics
ParameterMinTypicalMaxUnitNote
Output voltage53.5Vdc
12
Output voltage range+53.5V5057Vdc
+12V11.512.5
Output rated current range+53.5V08..5A
+12V03.0
Voltage regulation accuracy+53.5V±1.5%
+12V±2
Load regulation+53.5V±1.5%
+12V±2
Line regulation+53.5V±1%
+12V±2
Noise +ripple (peak to peak value)+53.5V150Vp-p
200(Low temperature-40°C)
+12V150
200(Low temperature-40°C)

Other output characteristics
ParameterMinTypicalMaxUnitNote
Output power464W
Output efficiency88%Rated voltage/rated load
85Full temperature range/full voltage range/rated load
Turn-on output delayNormal temperature 3s, low temperature 5ss220Vac input, full load output
Output rise time200msOutput voltage rise from 10% to 90%, rated load
Output overshoot5%+12Vdc and 53.5Vdc
Temperature coefficient±0.02%/°C

Protection
ParameterMinTypicalMaxUnitNote
Input over-voltage protection305330VacEach output with 50% load
Input over-voltage protection recovery290310VacEach output with 50% load
Input under-voltage protection125140Vac
Input under-voltage protection recovery141150Vac
Output over-voltage protection (53.5Vdc)5862VdcSelf-recovery,each output with 50% load
Output over-voltage protection (12Vdc)13.818.5VdcSelf-recovery, not affect 53.4vdc output
Output current-limiting protection(53.5Vdc)1015.5ASelf-recovery
Output current-limiting protection (12Vdc)47ASelf-recover,not affect 53.5Vdc output
Output short-circuit protectionFor long time short-circuit, self-recovery, +12Vdc shot-circuit not affect 53.5Vdc output.
Over-temperature protectionNo protection within normal working temperature

EMC and others
ParameterRequirementStandard
CECLASS BEN55022
RECLASS BEN55022
SURGELine-line 2kV; line-earth 4kVGB/T 17626.5Criterion A
EFTLEVEL 3: 2kVGB/T 17626.4Criterion A
DIP

Fall to 70%,40%,0%

duration: 10ms,100ms, 5000ms etc

EN61000-4-11

GB/T 17626.8

Criterion A( when exceed power input voltage range, select criterion B)
ESDContact discharge:±8kV. Air discharge: ±8kVGB/T 17626.4Criterion A
CSLEVEL 2:3V/m field intensityEN61000-4-6
RSLEVEL 2:3V/m field intensityGB/T 17626.3
Current Harmonic Emission

EN 61000-3-2

GB 17625.1

For AC power supply
Voltage Fluctuation And FlickerPst value not more than 1.0; P1t values not more than 0.65; relative steady voltage change not more than 3%; the largest relative voltage change dmax not more than 4%; time of voltage change device d (t) value more than 3% not longer than 200 ms

EN 61000-3-3

GB 17625.2

For AC power supply
AC Input Llightning Protection8/20μs waveform; line-line(5 times)5kA, line-earth(5 times)5kAGB/T 17626.5, Criterion B


Other requirements
ParameterTechnical requirements
High temperature agingAmbient temperature +55°C, 80% load, power on lasts 48 hours, the power supply should be able to work normally; take out and cool for 2 hours, the power supply should be able to work normally.Output work normally, with stable performance, no alarm
VibrationSample can bear 5Hz~500Hz random vibration at three mutually perpendicular directions, 5 hz ~ 10 hz frequency range, acceleration spectral density: 10m2/s3; 10Hz-200Hz freqrency range, acceleration spectral density: 3m2/s3; 200Hz-500Hz frequency range, acceleration spectral density: 1m2/s3; 20mins at each direction.(GB/T 2423.11)

After vibration, the power supply should be able to work normally,

normal output, stable performance, without alarm


ShockHalf sine wave, acceleration: 20g, pulse width: 11ms, X, Y, Z three directions: 3 times at each direction.(GB/T 2423.5)After shock, the power supply should be able to work normally.
Failure isolationAfter power module fails without output, the module is isolated, shall not do any harm on equipments and peoplePower supply module failure should not affect the power supply system
Component RequirementsThe inner components of power module must use industrial grade components.
Noise45dB(A), test distance: 1m
SmellNo peculiar and harmful smell
Environment ProtectionRoHS6
MTBF100000h

Safety and insulation grade
ParameterLevelStandard requirementTest conditions
Safety certificationDesign compliant with IEC60950,UL60950 and EN60950. Finished product have CE Certificate.

IEC60950

UL60950

EN60950

Insulation voltage

(input to output)


1500Vac

GB4943

GB/T13722

Bear 50Hz,1500V AC voltage for 1 minute, leakage current≤10mA, no flashover, no breakdown

Insulation voltage

(input to earth)


1500Vac
Insulation voltage(output to earth )500VdcBear 500V DC voltage for 1 minute,leakage current≤10mA, no flashover, no breakdown
Insulation resistance>10MΩEN60065Under normal atmospheric pressure, relative humidity 90%, testing voltage 500Vdc conditions, the insulation resistance of rectifier main circuit AC/DC part to earth, and AC part to DC part shall be no less than 10MΩ.
Grounding resistance<0.1ΩGB4943
Contact current<3.5mAGB4943

Mechanical specifications
L×W×H (mm)As the following diagram
Weight(kg)≤1.3Kg


3.Signal



Terminal definition table
Terminal no.Pin no. (from left to right)Screen printingOutput voltage definitionNote
Input terminal1LAC input live wireInterface use VH5.08-3P connector
2NAC input neutral wire
3PEEarthing
Output terminal1+53.5V53.5V output +Interface use VH5.08-4P connector and VH5.08-2Pconnector
2+53.5V53.5V output +
3GND53.5V Output earth
4GND53.5V output earth
5+12V12Vdc output +
6GND12Vdc output earth
Monitoring terminal1AC/OKAC input alarm signal2001S-3P(Pin pitch 2.54mm, Pin diameter 0.64mm)
2DC/OKDC output alarm signal
3GNDAlarm earth

4. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


5. Our Contact Information


Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

Quality Commercial Power Supply , Professional Power Supply ISO9001 CE Certification for sale
Send your message to this supplier
 
*From:
*To: Tianjin Estel Electronic Science and Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly